Tactical Flow Meter, Thermal Mass Flow Meters, MAG and Coriolis Meters

1/2″, 1″, 2″, 3″ & 4″ ANSI PIPE FLANGE SIZE RANGES

Vortex Mass Flow Meters on the costs of high-end Thermal Mass Flow Meters and are at 1% of READING.

Vortex Meter Digital Display

Multivariable Vortex Meter

See the video beneath to see how one can use the buttons on the show inside the enclosure. 

Features LARGE LCD show, reveals the Flow Rate, Total Flow, Temperature, and Pressure in person selectable items.

Vortex Manual

 Vortex Meter Specifications.

  • Wetted Materials all 304 SS 
  • Velocity Range: See element beneath.
  • Velocity Accuracy: +/- 1% of studying
  • Repeatability of +/- 0.05% of studying
  • 1/2″ to 4″ 150# ANSI Flange Connections, as much as 12″ obtainable customized.
  • LCD Display
  • Temperature Accuracy +/- 1 Deg C
  • Temperature:         
    • Gas: -40°F (-40°C) to 482°F (250°C)
    • Std Temp Liquid: -40°F (-40°C) to 662°F (350°C)
    • High Temp Liquid: -40°F (-40°C) to 626°F (330°C)[Add $450]
    • Ambient: -40°F (-40°C) to 131°F (55°C)              
  • Power Requirement: 24 VDC, 15 Watts most;   
  • 3.6 VDC Lithium C Size battery for intrinsic security mode. Has LCD Display however no 4-20 or ModBus
  • Output indicators: Modbus RTU, 4–20 mA, and 0-1.0 OkHz for move charge indication
  • Digital communications: Modbus RTU
  • Max Pressure 1.6 MPa, 230 PSIG. (Custom as much as 4.0 MPa 580 PSIG)
  • Display: Flow charge, Total move, Temperature, and Pressure
  • Wiring connection to enclosure dimension: M20 x 1.5
  • Factory Final QC Test Certificate
  • Integral Electronics
  • Electronics Enclosure NEMA 4X / IP67

Vortex Meter Velocity Ranges:

The Vortex meter has completely different minimal and most move velocities it might measure primarily based on the fluid sort and meter dimension. Please be aware the values beneath for correct sizing of your meter. 

1/2” ANSI Flange: 4-70m/s or 787-13,800 f/m or 13-230 f/s

1” ANSI Flange: 3-70m/s or 590-13,800 f/m or 9.8-230 f/s

2” to 12” ANSI Flange: 1.5-70m/s or 30.2-13,800 f/m or 4.92-230 f/s

1/2” ANSI Flange: 4-65m/s or 787-12,790 f/m or 13-213 f/s

 1” ANSI Flange: 3-65m/s or 590-12, 790 f/m or 9.8-213 f/s

2” to 12” ANSI Flange: 1.5-65m/s or 300- 12,790 f/m or 4.9-213 f/s

1/2” to 12” ANSI Flange: 0.2-10m/s or 40- 1,968 f/m or .66-32.8 f/s

Nominal Vortex Flow Rates for Air

The desk beneath provides the minimal, nominal, and most velocities for the Vortex Meter for gases to help customers accustomed to Thermal Mass Flow Meter sizing guides relative to air, with a density of 0.075 lb/ft^3 for reference. As the strain goes up the flows go up as properly. For instance, if the strain is DOUBLED, so too does the mass move. Download chart beneath right here:

Vortex Flow Rate Chart Tactical Flow Meter

 IMPORTANT Note to Thermal Mass Flow Meter customers…

Did you realize that Multivariable Vortex Flow Meters provide a major benefit over Thermal Mass Flow Meters when it’s not essential to measure extremely low or extremely excessive flows?

Did you realize {that a} Multivariable Vortex Meter is just not affected by fuel composition? This means you may change fuel composition and STILL report the correct Mass Flow! Why make the most of a Gas Chromatograph to find out fuel composition to right your Thermal Mass Flow Meter measurement? If you want extremely low flows it is sensible but when your minimal flows are inside the measuring vary of a Vortex meter then take into account a Multivariable Vortex Mass Flow Meter.

As properly, it is very important be aware that Thermal Mass Flow Meters are fairly delicate to moisture within the move stream. The commonest undesirable impact is momentary move spikes that may upset your management system. Vortex Meters, alternatively are NOT delicate to moisture within the move stream and provide a major benefit over Thermal Mass Flow Meters if such spikes are decided to be undesirable.

Have you ever have issues with temperature swings inflicting your Thermal Mass Flow meter to over or underneath report the move measurement? The Multivariable Vortex Mass Flow Meter doesn’t exhibit these signs just because the vortex shedding velocity is just not a perform of temperature or strain. And, with the Multivariable Vortex Meters in-built Pressure and Temperature sensors you will get true Mass Flow, Pressure, AND Temperature and even collect Volume move on these uncommon events when deemed crucial. And, you may have a real strain measurement in addition to the Mass Flow and temperature. All at a worth very aggressive with Thermal Mass Flow Meters.

HOWEVER, in case you DO want very low or very excessive flows we advise the usage of Thermal Mass Flow Meters. As properly, Thermal Mass Flow Meters are supreme as “Insertion Meters” as they’re small and if, and ONLY if, there isn’t any moisture, or fuel composition adjustments then the Thermal Mass Flow Meter is an excellent selection.  Otherwise, the Vortex is the only option because it has NO sensitivity to the fuel composition or droplets or hydrocarbon particulate.

Refer to the chart above for the minimal and most flows for the Vortex Mass Flow Meter. Refer to the minimal and most velocities for the fluid you want to use to see if a vortex meter is an effective selection. If your move is inside the velocity vary of the Vortex meter AND you may have moisture or any change in fuel composition then a Vortex meter is a more sensible choice over the Thermal Mass Flow Meter. 

Vortex Multivariable Flange Meter Dimensions with 150# ANSI B 16.5 Flanges

Multivariable Vortex Meter Dimensions, TacticalFlowMeter.com

Vortex Meter Specifications and Dimensions:


Download Brochure
 , Specifications, Cut Sheet, and Dimensions.

 

Important Note: Vortex Flow Meters wish to be rigidly mounted or remoted from vibration to forestall the vibrating vitality to be transmitted to the Vortex Piezo Sensors. This will be achieved by inflexible mounts to a stable base or good vibration isolation.

How to make use of button interface and ModBus RTU video:To get probably the most out of the video open the hyperlink beneath and print out the doc or open it in one other window.

ModBus instructions and Meter codes

Vortex Manual

How to Invoke Variable Ok-Factors within the Tactical Flow Meter Vortex Flow Meter:

Screen 33 Instructions are for superior customers solely. Do NOT invoke this display screen in your meter until you may have a urgent want. It is essential to notice all settings PRIOR to creating any adjustments. Note: Left button HOLD will get you OUT of menus.

See instance spreadsheet right here

Video exhibiting how one can use the spreadsheet above and the Front Panel Interface with Menu 33:

Before exiting make sure you SAVE the info and CONFIRM the % numbers are ever rising in from factor 0 to factor 4. The Correction ratio should be between 0.8 and 1.2.

 Where to get Power Supplies, Gaskets, Nuts and Bolts Link

Important Note: Vortex Flow Meters wish to be rigidly mounted or remoted from vibration to forestall the vibrating vitality to be transmitted to the Vortex Piezo Sensors. This will be achieved by inflexible mounts to a stable base or good vibration isolation. We present some settings beneath as examples in your examine. The video above reveals how one can enter the configuration modes.

Typical Vortex Meter Settings for studying Volume Flow for Liquids with a Full Scale of 250 l/m for a fluid with a density of 875 kg/m3 for a 3″ Vortex Meter the place the vortex frequency is from 34-850 Hz.

How to confirm and arrange Full Scale and Units: 

Refer to the Vortex Meter LCD Interface Video above for overview and introduction to utilizing buttons.

Vortex Meter Menu Details

MENU 22
Q Unit >> l/m
Q Mode >> Qvw precise (We are measuring quantity move….)
Q Factor >> 2121.47  Do Not Change (This is stamped on the aspect of the meter)
Density >> 875 kg/m3 (Water is 1000)
Q20mA >> 250 (FULL SCALE… If your meter is 250 l/m)
Q Cut-Zero % >> 5
Q Up Al >> 250 to show the alarm on at 100%
Q Dn Al >> 25 to show the alarm at 10% move
Damp S >> 6
Comm Address >> 0
Clear Q >> Clears Totalizer, Password = 70

MENU 33
Language >> English
Pulse Type >> F_adj
Pulse Factor >> 0.01
Comm Param >> 9600, No
Comm Switch >> ON
P_display >> MEASURE
Set Pc >> 0
P0-Ref >> 101.3KPa
T_display >> MEASURE
Set Tc >> 20 Deg C
T-TYPE >> Pt=100
Tn >> 20 Deg C
Environ-T >> -20 Deg C (-10 C is okay if you don’t get them chilly.)
Q-adj >> DO NOT change this setting

MENU 44
Signal-TYPE >> LF: DN40-500 Lqd
Gain >> G=9
VPP restrict >> 100mV
Fre-Range >> 11=34-850Hz
Work Type >> Digital
an-noise TYPE >> ANS
Signal-Adj-Set >> FIlter 10 or OFF
50Hz Cut >> ON
Ok-LINE ADJ >> DO NOT change this setting